Catalog 1308242
Protective Cover & Mounting Clip Dimensions
Issued 3-03
P&B
SSA-24C668
Protective Cover
1.99
.40
SSA-24C667
Mounting Clip
“A
(50.5)
(10.2)
2.283 1.970
(58.0) (50.0)
1.99
(50.5)
2.047
(52.0)
1.654
.591
(15.0)
“A
Section "A-A"
(42.0)
1.890
(48.0)
Programming Switch Diagram
With this setting, the relay would operate after a delay period of 214 seconds.
A
2
1
4
S
Function Select:
Timer Mode:
Counter Mode:
A = Delay On Operate
B = Delay On Release
C = Interval On
D = Control-Off Interval On
B = Divide by 10
E = Recycle
F = Single Cycle
G = Control On-Off Interval On
H = Control On-Off Delay
C = Divide by 100
I = Pulse
J = Cumulative Delay On Operate
A & D-J = Normal Count
Time/Counter Setting: 001 to 999
Time Base/Counter Mode Select:
Time Base:
Counter Mode:
.1S = 0.1 to 99.9 Sec. .1M = 0.1 to 99.9 Min. .1H = 0.1 to 99.9 Hrs.
S = 1 to 999 Sec. M = 1 to 999 Min. H = 1 to 999 Hrs.
CO = Operate at Preset Count CR = Release at Preset Count
10H =10 to 9990 Hrs.
Timer Function Descriptions
A . Delay On Operate
Output relay turned on at end of programmed time interval which is started
by CONTROL input or power-on with CONTROL on. Relay turned off by
RESET input until next cycle is started. With CONTROL on, turning RESET
off restarts timing
B. Delay On Release
Output relay turned on with CONTROL input and remains on for programmed
time interval following removal of CONTROL. During time interval after
release of CONTROL, RESET turns relay off until cycle restarted with
reapplication of CONTROL. With CONTROL on, relay is held off while
RESET is activated.
C. Interval On
Output relay turned on for programmed time interval by CONTROL or power-
on with CONTROL on. RESET turns relay off until next cycle is started, and
does not restart timing when RESET is removed.
D. Control-Off Interval On
Output relay turned on for programmed time interval by turn-off of CON-
TROL. RESET turns relay off until next cycle is started, and does not restart
timing when RESET is removed.
E. Recycle
Output relay turned on at end of programmed time interval which is started
by momentary CONTROL input or power-on with CONTROL on. Relay stays
on for equal time interval, then turns off and cycle is repeated on a free-
running basis until terminated by momentary RESET, turning relay off. With
CONTROL on, turning RESET off restarts cycle.
F. Single Cycle
Output relay turned on at end of programmed time interval which is
Counter Function Descriptions
CO – Operate at Preset Count – Normal Mode
After initializing by momentary activation of RESET input, each on/off signal
at COUNT (CONTROL) input increments displayed count in upcounting
manner from initial 000 value until preset count, set by thumbwheel
switches, is reached and output relay turns on. Additional inputs continue to
increment displayed count. Continued counting past maximum count (999)
results in a “wrap-around” effect to 000, followed by contrinued up-counting.
Activation of RESET input turns relay off and resets count to zero.
started by momentary CONTROL input or power-on with CONTROL
on. Relay stays on for equal time interval, then turns off. RESET
terminates timing and turns relay off. Turning RESET off does not restart
timing.
G. Control On-Off Interval On (Watch Dog Timer)
Output relay turned on and programmed time interval started or restarted
by change of CONTROL input. RESET turns relay off and stops timing.
Turning RESET off does not restart timing.
H. Control On-Off Delay
Output relay turned on at end of programmed timing interval which is
started or restarted by change of CONTROL input. If relay is on, turn-off
of relay occurs at end of programmed time interval which is started or
restarted by change of CONTROL input. RESET turns relay off and stops
timing. Turning RESET off does not restart timing.
I. Pulse
Output relay turned on at end of programmed time interval, which is
started by CONTROL input, for 0.5 second duration, and continues in
pulsed mode at programmed time interval with fixed 0.5 second on-time.
Turning CONTROL off turns relay off and stops timing. RESET turns relay
off and inhibits operation. With CONTROL on, removal of RESET restarts
timing.
J. Cumulative Delay On Operate
Output relay turned on at completion of total accumulate CONTROL input
duration equal to programmed time. Turning CONTROL off before
accumulation of programmed time results in measured time total being
held until CONTROL is again turned on and total programmed time value
is reached. RESET input resets time value to zero and turns relay off if
energized. Turning RESET off restarts timing if CONTROL is on.
CR – Release at Preset Count – Normal Mode
Initializing by momentary activation of RESET input turns relay on. Operation
is similar to CO (Operate at Preset Count) except relay turns off at a preset
count.
CO or CR – Divide-by-10 Mode
Operation is as described previously, except count is incremented for every
10 on/off input signals for a maximum presettable count of 9,990.
CO or CR – Divide-by-100 Mode
Operation is as described previously, except count is incremented for every
100 on/off input signals for a maximum presettable count of 99,900.
Dimensions are shown for
1212 reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
相关PDF资料
1.20126.4030000 CONTACT BLOCK E-STOP AU 1NO 1NC
SSP-MTCV1 SWIVEL MOUNTING CLIP FOR LT BAR
HWK-40-000/A BEZEL PANEL ADAPTER FOR HWK40000
1.20122.0620000 CONTACT BLOCK LAT 2NO
1.20122.0020000 CONTACT BLOCK MOM 2NO
561-1201-050 LED 5MM VERT LOW CUR YELLOW PCMT
561-1101-090 LED 5MM VERT LOW CUR RED PC MNT
3020-01096-0 SHUNT CURRENT DC 50A/50MV
相关代理商/技术参数
SSA-24C668 制造商:MACOM 制造商全称:Tyco Electronics 功能描述:Multifunction, Digital Time Delay Relay/Counter
SSA24-E3 制造商:Vishay Semiconductors 功能描述:RECTIFIER, 2A, 40V, SM SCHOTTKY
SSA24-E3/2G 制造商:Vishay Semiconductors 功能描述:SCHOTTKY 40V 2A 2PIN SMA - Tape and Reel
SSA24-E3/5A 制造商:Vishay Semiconductors 功能描述:SCHOTTKY 40V 2A 2PIN SMA - Tape and Reel
SSA24-E3/5AT 功能描述:肖特基二极管与整流器 40 Volt 2.0 Amp 60 Amp IFSM RoHS:否 制造商:Skyworks Solutions, Inc. 产品:Schottky Diodes 峰值反向电压:2 V 正向连续电流:50 mA 最大浪涌电流: 配置:Crossover Quad 恢复时间: 正向电压下降:370 mV 最大反向漏泄电流: 最大功率耗散:75 mW 工作温度范围:- 65 C to + 150 C 安装风格:SMD/SMT 封装 / 箱体:SOT-143 封装:Reel
SSA24-E3/61 制造商:Vishay Semiconductors 功能描述:SCHOTTKY 40V 2A 2PIN SMA - Tape and Reel
SSA24-E3/61T 功能描述:肖特基二极管与整流器 2.0 Amp 40 Volt RoHS:否 制造商:Skyworks Solutions, Inc. 产品:Schottky Diodes 峰值反向电压:2 V 正向连续电流:50 mA 最大浪涌电流: 配置:Crossover Quad 恢复时间: 正向电压下降:370 mV 最大反向漏泄电流: 最大功率耗散:75 mW 工作温度范围:- 65 C to + 150 C 安装风格:SMD/SMT 封装 / 箱体:SOT-143 封装:Reel
SSA24-E3/61T 制造商:Vishay Semiconductors 功能描述:SCHOTTKY RECTIFIER 2A 40V DO-214AC